Print

Skipping channels when deconvolving with Huygens Pro?


In Huygens Pro, there is a deconvolution wizard and an operation window. Using the operations window all channels are processed in one run. To work with only one channel proceed to split the multichannel image (Select Edit->Split or ALT-S) into single channel images. The single channel images can be deconvolved individually with specific parameter values. For example, the SNR can be edited in the "Signal/Noise per channel" input line of the Operations window. The Join operation can be used after the deconvolution of single channel images to combine them into a multichannel image.

Wihthin the devonvolution wizard, you can choose which channel you want to process and skip those you are not interested in.

Keywords: 2-channel two-channel SNR signal noise join split
Categories: Faq Deconvolution, Faq Microscopy, Huygens Faq, Imported Faqs
Platforms: Irix Linux
Related products: Hu Pro